20% OFF shipping at www.paixalia.com on orders over $79 + up to 10% OFF products
www.paixalia.com
home > Wilkins 2-950XLTDABFSSLM | Double Check Detector Backflow Preventer, 2 Inches > Wilkins 2-950XLTDABFSSLM | Double Check Detector Backflow Preventer, 2 Inches
download picture
Wilkins 2-950XLTDABFSSLM | Double Check Detector Backflow Preventer, 2 InchesNOTICE: Product images may vary from the actual item due to differences in size or configuration options. The Wilkins 2 950XLTDABFSSLM is a double check detector backflow preventer designed for fire protection systems, providing reliable protection against backsiphonage and backpressure with supervisory switch monitoring. Key Specifications: Size: 2 Inches Maximum Working Water Pressure: 175 PSI Maximum Working Water Temperature: 180F Notable
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

NOTICE: Product images may vary from the actual item due to differences in size or configuration options.

The Wilkins 2-950XLTDABFSSLM is a double check detector backflow preventer designed for fire protection systems, providing reliable protection against backsiphonage and backpressure with supervisory switch monitoring.

 

Key Specifications:

  • Size: 2 Inches
  • Maximum Working Water Pressure: 175 PSI
  • Maximum Working Water Temperature: 180°F
  • Notable Certifications: ASSE 1048, UL, C-UL Classified
  • End Connections: FNPT inlet/outlet threaded

 

Other Related Variants:

  • 2-950XLTDABFSS: Model with supervisory switches and water meter included

 

Materials:

  • Main valve body: Cast Bronze ASTM B584
  • Access covers: Cast Bronze ASTM B584
  • Fasteners: Stainless Steel, 300 Series
  • Elastomers: Silicone (FDA approved) and Buna Nitrile (FDA approved)
  • Polymers: NSF Listed Noryl™
  • Springs: Stainless Steel, 300 series
  • Test cock cover: Plastic

 

Typical Installation:

Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Suitable for both horizontal and vertical orientations.

 

Standards Compliance:

ASSE Listed 1048; UL Classified; C-UL Classified; AWWA Compliant C510; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; NSF/ANSI/CAN 61 & 372 compliant

 

Features & Benefits:

  • Comprehensive Backflow Protection: The Zurn 2-950XLTDABFSSLM protects against both backsiphonage and backpressure in fire protection and potable water service lines.
  • Supervisory Monitoring Capability: Equipped with butterfly valve supervisory switches (UL and FM approved) for indoor and outdoor use, enabling real-time monitoring of valve position.
  • Flexible Installation: Approved for both horizontal and vertical installation orientations, providing versatility in system design and space constraints.
  • Durable Construction: Bronze body with 300 series stainless steel internals and FDA-approved silicone elastomers ensure long-lasting performance and compliance with lead-free standards.

 

FAQ

 

Q: What is the "LM" designation in the Wilkins 2-950XLTDABFSSLM model number?

A: The "LM" suffix indicates "less meter," meaning this configuration includes the bypass arrangement ready for meter installation but does not include an installed water meter.

Q: Can the Zurn 2-950XLTDABFSSLM be installed vertically?

A: Yes, this assembly is approved for both horizontal and vertical installation according to ASSE 1048 standards and manufacturer specifications.

Q: What type of hazard protection does this backflow preventer provide?

A: This double check detector assembly provides protection where a low health hazard potential exists, suitable for fire protection systems with metered bypass to detect leaks and unauthorized water use.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.

"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us

Wilkins 2-950XLTDABFSSLM | Double Check Detector Backflow Preventer, 2 Inches

Item no : 16746788970
sold recently : Login >>
US$ 1872.99
Pay in 4 interest-free payments of $468.25 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 27 - Aug 1

Enjoy 20% off shipping

US$ 1872.99

1-11

US$ 1685.69

12-35

US$ 1311.09

36-59

US$ 1123.79

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches