20% OFF shipping at www.paixalia.com on orders over $79 + up to 10% OFF products
www.paixalia.com
home > GIO212 Bachmann Universal Input/Output Module | New & Original Stock > GIO212 Bachmann Universal Input/Output Module | New & Original Stock
download picture
GIO212 Bachmann Universal Input/Output Module | New & Original StockBachmann GIO212 M1 Automation System The Bachmann GIO212, also cataloged as the GIO212 Universal Input Output Module, operates as a dedicated hardware component for multi signal analog and digital interfacing within Bachmann M1 Automation System platforms. Hardware Specifications Parameter Specification Model GIO212 Brand Bachmann Electronic Origin Austria Germany Weight 0. 5 kg Dimensions 160 mm x 100 mm x 40 mm Operating Temp 25 to +70 deg C Power
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Bachmann GIO212 M1 Automation System

The Bachmann GIO212, also cataloged as the GIO212 Universal Input/Output Module, operates as a dedicated hardware component for multi-signal analog and digital interfacing within Bachmann M1 Automation System platforms.

Hardware Specifications

Parameter Specification
Model GIO212
Brand Bachmann Electronic
Origin Austria / Germany
Weight 0.5 kg
Dimensions 160 mm x 100 mm x 40 mm
Operating Temp -25 to +70 deg C
Power Consumption 5 W
Configurable Channels 16 channels (analog/digital configurable input or output)
Analog Signal Resolution 16-bit A/D and D/A conversion
Analog Input Ranges +/-10 V, 0/4-20 mA, Pt100/Pt1000, Thermocouples
Digital Input Rating 24 VDC (15-30 VDC range), ~ 7 mA per channel
Digital Output Rating 24 VDC, 0.5 A per channel max
Signal Isolation Optical isolation between channels and system bus
Execution Response Time <= 1 ms

I/O Density Scaling and Backplane Integration

The universal interface module utilizes embedded parameter registers to adjust electrical execution paths on a per-channel basis, adapting local I/O density scaling profiles without modifying the physical footprint of the backplane sub-assembly. Internal high-velocity backplane bus communication pathways facilitate the transmission of high-resolution 16-bit analog conversions, 32-bit counter metrics, and fast binary transitions directly to the runtime engine kernel. This software-defined routing mechanism maintains strict hardware timing tolerances while ensuring permanent firmware flash compatibility with the primary M1 processor platform during active operations.

Frequently Asked Questions

Q: How does the internal backplane logic respond when changing channel parameters between analog and digital functions?

A: Channel configuration matrices are locked during the initial controller boot sequence via the system configuration files. Modifying channel assignments requires a complete restart of the M1 rack to upload new hardware profiles over the backplane bus communication interface.

Q: Is this universal hardware component hot-swappable on an energized M1 base unit?

A: No. The backplane design does not support active hot-swap functionality. Power to the M1 base rack must be isolated prior to removing or seating the module to protect the internal optical isolation components from transient voltage damage.

Q: What buffering capacity is available for high-speed digital counter or period measurement operations?

A: The module contains an integrated physical hardware FIFO buffer capable of storing up to 1022 timed values for pulse length and period measurements, insulating the data from backplane bus communication latencies.

Field Installation Guidelines

  • Backplane Socket Alignment: Insert the module housing straight into the M1 base unit guide channels, applying even pressure until the multi-pin rear connector is fully seated into the passive backplane.
  • Shield Grounding Matrix: Clamp all analog instrumentation and high-speed digital signal cable shields to the low-impedance master cabinet ground bus at the physical entry partition.
  • Conductor Type Segregation: Maintain separate physical wiring paths for 24 VDC digital actuation loops, low-level RTD/thermocouple signals, and adjacent high-voltage power lines.
  • Thermal Boundary Clearances: Verify a minimum vertical gap of 50 mm above and below the module ventilation openings to permit unobstructed convection airflow through the assembly.

GIO212 Bachmann Universal Input/Output Module | New & Original Stock

Item no : 30857372693
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 1 - Aug 6

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches